Shenzhen UniMAT Automation Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Peng Jeff
  • Company Name : Shenzhen UniMAT Automation Technology Co., Ltd.
  • Tel : 86-755-26504047
  • Fax : 86-755-26504049
  • Address : Guangdong,Shenzhen,F/4, AVIC Nanhang Building, No. 7 Langshan Road, High-Tech Park, Nanshan District
  • Country/Region : China
  • Zip : 518057

CPU224 AC/DC/Relay 16 Inputs & 10 outputs SCADA Equipment

CPU224 AC/DC/Relay 16 Inputs & 10 outputs SCADA Equipment
Product Detailed
Related Categories:Other Electronic Components
1. High quality SCADA Equipment; 2. CE Approval Cpu; 3. Program memory:50KB; 4. Strong capabilities of high-speed computering High quality SCADA Equipment: 224 series AC/DC /Relay Cpu.  Warranty :5-year warranty on product quality,5-year warranty means replacement within half a year and lifetime maintenance.  High quality assurance:CE CertificateISO 9001-2008  Packaging & Delivery:Packing Details:Standard Packing;Delivery Detail : Ex Stock Detail Description: 
Technical specifications
ModelCPU224 AC/DC/Relay
Physical characteristic
Dimensions(W x H x D)(mm)120.5×80×62
Power consume10W
Memory  
Program memory size 
With run mode edit25K bytes
Without run mode edit50K bytes
Data memory20408bytes
I/O 
Local digital inputs14 inputs
Local digital outputs10 outputs
Digital I/O image size256(128 inputs/128 outputs)
Analog I/O image size64(32 inputs/32 outputs)
expansion modules allowed (Max)7 modules
intelligent modules allowed (Max)7 modules
Pulse catch inputs14
High-speed counters6 counters total
Single phase6 at 30KHz
General 
TimerTotal number:256(1ms:4;10ms:16;100ms:236)
Counters256
Time interrupts2 with1ms resolution
Edge interrupts4 up and/or 4 down
Analog adjustment2 with 8 bit resolution
Real Time ClockBuilt-in
Power 
Input voltage85 to 264 V AC(47 to 63Hz)
Input current60/30mA while CPU only at 120/240V AC
200/100Ma while Max. load at 120/240V AC
Inrush current20A at 264 V AC
Hold up time(loss of power)1s at 120/240 V AC
Sensor voltage20.4 to 28.8 V DC
Current limit1.5A peak, thermal limit non-destructive
Ripple noise (sensor to logic)Less than 1V peak-to-peak
CPU Digital Input Specifications
Built-in digital input14 inputs
Input typePNP/NPN
Rated voltage24 V DC at 4mA
Max. continuous permissible voltage30V DC
Surge voltage35 V DC,0.5s
Logic “1” voltage range15 to 30 V DC
Logic “0” voltage range0 to 5 V DC
Input delaySelectable (0.2 to 12.8ms)
Isolation (field to logic)Yes
Optical galvanic500 V AC for 1minute
Isolation groupsRefer to Wiring diagram
HSC logic level 1(15 TO 30 VDC)20K Hz (Single phase), 10K Hz (Tow phase)
HSC logic level 1(15 TO 26 VDC)30K Hz (Single phase), 20K Hz (Tow phase),
Inputs on simultaneouslyall
Shielded500m normal inputs, 50m HSC inputs
unshielded300m normal inputs
CPU Digital Output Specifications
Built-in outputs10 outputs
Output typeDry contact
Rated voltage24 V DC or 250 V AC
Voltage range5 to 30 V DC or 5 to 250 V AC
Surge current (Max.)5A for 4s at 10% duty cycle
Rated current per point(Max.)2.0A
Rated current per common(Max)10A
Order numberUN 214-1BD23-0XB0
Our customers Said:♥    ♥♥ 

CPU224 AC/DC/Relay 16 Inputs & 10 outputs SCADA Equipment



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.